Cold test
Measured temperature /
sample name |
Protection against cold |
102 |
103 |
104 |
-70℃ |
passed |
passed |
passed |
-65℃ |
passed |
passed |
passed |
-60℃ |
passed |
passed |
passed |
Test request destination :Chemicals Evaluation and Research Institute
※ -70 ℃ is the limit measurements .
Test Date : September 20, 2005
Not detected most of the material , it has proven the safety of the Dairobu gloves .
Test Date : September 28, 2005 ( Unit : mg / ℓ)
A96 test Date : September 24 , 2014 ( Unit : mg / ℓ)
Test request destination :Chemicals Evaluation and Research Institute
Combustion gas test(JIS K 2541)
Test item / sample name |
① |
② |
③ |
④ |
⑤ |
H202 |
550 |
5000 |
H40 |
102 |
104 |
H200 |
Hydrogen fluoride (HF) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Hydrogen chloride (HCl) |
passed |
4.1 |
passed |
passed |
1.6 |
1.8 |
passed |
0.1 |
Hydrogen bromide(HBr) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Hydrogen cyanide (HCN) |
passed |
0.22 |
0.25 |
0.16 |
0.12 |
0.059 |
0.012 |
0.005 |
Sulfur oxides (SOx) (SO₂ Conversion) |
passed |
passed |
passed |
1.3 |
0.3 |
0.4 |
passed |
0.1 |
Nitrogen oxide (NOx) (NO₂ Conversion) |
passed |
1.7 |
1.4 |
1.2 |
2.2 |
1.7 |
4.6 |
0.5 |
①For solvent ②Antistatic ③Protection against cold ④For heat ⑤lower limit
800 is a test to burn at ± 50 ℃.
Test request destination :Chemicals Evaluation and Research Institute
Test Date : 16 Oct 2005 ( Unit : mg / g)
Analytical test
Test items |
① |
② |
③ |
④ |
H202 |
20 |
102 |
104 |
H200 |
Material testing |
Cadmium and lead |
Limit below |
passed |
Limit below |
Limit below |
Limit below |
Dissolution test |
Phenol |
passed |
passed |
passed |
passed |
passed |
Formaldehyde |
passed |
passed |
passed |
passed |
passed |
zinc |
passed |
passed |
passed |
passed |
passed |
heavy metal |
passed |
passed |
passed |
passed |
passed |
Evaporation residue ( water ) |
passed(10ppm) |
passed(36ppm) |
passed(18ppm) |
passed(5ppmbelow) |
passed(5ppmbelow) |
Test items |
⑤ |
H3 |
223 |
440 |
550 |
5500 |
H201 |
H202 |
Material testing |
Cadmium and lead |
passed |
Limit below |
Limit below |
Limit below |
Limit below |
Limit below |
passed |
Dissolution test |
Phenol |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
Formaldehyde |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
zinc |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
heavy metal |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
Evaporation residue ( water ) |
passed(31ppm) |
passed(11ppm) |
passed(13ppm) |
passed(19ppm) |
passed(34ppmbelow) |
passed(5ppmbelow) |
passed(5ppmbelow) |
①For oil ②For solvent ③For solvent ④Protection against cold ⑤For heat ⑥For solvent
Food , were tested in accordance with the third of the three rubber equipment or containers and packaging of D of the standard criteria of the additives,
etc. ( 1959 Ministry of Health and Welfare Notification No. 370 ) .
Dissolution test
|
Cl, analysis of the content of Br
Pb, cCd, T-Cr, analysis of the content of Hg |
Test items |
① |
② |
⑥ |
H3 |
20 |
440 |
550 |
5000 |
H202 |
102 |
103 |
104 |
Bromine ion (Br⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Calcium (Ca) |
passed |
passed |
passed |
passed |
passed |
passed |
0.3 |
passed |
passed |
0.2 |
Chlorine ion (Cl⁻) |
passed |
passed |
0.4 |
3.2 |
passed |
0.2 |
1.7 |
3.1 |
1.1 |
0.1 |
Fluorine ion (F⁻) |
passed |
passed |
passed |
2.4 |
passed |
不検出 |
passed |
不検出 |
passed |
0.1 |
Sodium (Na) |
passed |
passed |
passed |
passed |
passed |
0.1 |
passed |
0.05 |
passed |
0.05 |
Nitrate ion (NO₃⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Phosphate ion (PO₄³⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Potassium (K) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.05 |
Copper (Cu) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
Test items |
③ |
④ |
⑤ |
⑥ |
H200 |
H4 |
H40 |
300 |
3000 |
A95 |
A96 |
A96以外 |
A96 |
Bromine ion (Br⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
0.1 |
Calcium (Ca) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.2 |
0.1 |
Chlorine ion (Cl⁻) |
0.1 |
passed |
passed |
1.5 |
passed |
0.2 |
0.2 |
0.1 |
0.1 |
Fluorine ion (F⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
0.1 |
Sodium (Na) |
0.05 |
passed |
passed |
passed |
passed |
passed |
passed |
0.05 |
0.1 |
Nitrate ion (NO₃⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
0.1 |
Phosphate ion (PO₄³⁻) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
0.1 |
Potassium (K) |
0.05 |
passed |
passed |
passed |
passed |
passed |
passed |
0.05 |
0.1 |
Copper (Cu) |
passed |
passed |
passed |
passed |
passed |
passed |
passed |
0.1 |
0.1 |
①For solvent ②Protection against cold ③For heat ④Antistatic ⑤For acid resistance and alkali ⑥lower limit
Not detected most of the material , it has proven the safety of the Dairobu gloves .
Test Date : September 28, 2005 ( Unit : mg / ℓ)
A96 test Date : September 24 , 2014 ( Unit : mg / ℓ)
Test request destination :Chemicals Evaluation and Research Institute
Ignition point test (ASTM E 659)
Test items |
H200 |
outer |
inner |
Ignition point (℃) |
448 |
429 |
Test request destination :Chemicals Evaluation and Research Institute
Test Date : September 20, 2005
Moisture permeability test(JIS Z 0208)
est items |
H3 For solvent |
Third-party |
Moisture permeability (g / m 2 · 24hr) |
2248 |
1824 |
Water vapor permeability coefficient (g · mm / m 2 · 24hr) |
164 |
141 |
Test Date : July 28, 2004
Test request destination :Chemicals Evaluation and Research Institute
Breakthrough time measurement test(EVOH)
CAS NO. |
Solvent name |
Chemical formula |
*ASTM breakthrough time |
Indication |
67-64-1 |
※ acetone |
CH₃COCH₃ |
8 hours undetected |
◎ |
27522 |
※ acetonitrile |
CH₃CN |
8 hours undetected |
◎ |
141-78-6 |
※ Ethyl acetate |
CH₃COOC₂H₅ |
8 hours undetected |
◎ |
109-89-7 |
※ diethylamine |
(C₂H₅)₂NH |
8 hours undetected |
◎ |
27639 |
※ dichloromethane |
CH₂Cl₂ |
8 hours undetected |
◎ |
25174 |
※ dimethylformamide (DMF) |
(CH₃)₂NCHO |
8 hours undetected |
◎ |
127-18-4 |
※ tetrachlorethylene |
CCl₂₌CCl₂ |
8 hours undetected |
◎ |
109-99-9 |
※ tetrahydrofuran (THF) |
C₄H₈O |
8 hours undetected |
◎ |
108-88-3 |
※ toluene |
C₆H₅CH₃ |
8 hours undetected |
◎ |
98-95-3 |
※ nitrobenzene |
C₆H₅NO₂ |
8 hours undetected |
◎ |
75-15-0 |
※ carbon disulfide |
CS₂ |
8 hours undetected |
◎ |
110-54-3 |
※ n- hexane |
CH₃(CH₂)₄CH₃ |
8 hours undetected |
◎ |
67-56-1 |
※ methanol |
CH₃OH |
315 minutes |
○ |
7664-93-9 |
※ 93.1% sulfuric acid solution |
H₂SO₄ |
8 hours undetected |
◎ |
1310-73-2 |
※ aqueous solution of sodium hydroxide 50% |
NaOH |
8 hours undetected |
◎ |
872-50-4 |
N- methylpyrrolidone |
C₅H₉NO |
8 hours undetected |
◎ |
512-56-1 |
Trimethyl phosphate |
(CH₃O)₃PO |
8 hours undetected |
◎ |
67-63-0 |
Isopropyl alcohol (IPA) |
CH₃CH(OH)CH₃ |
8 hours undetected |
◎ |
95-47-6 |
0- xylene |
C₆H₄(CH₃)₂ |
8 hours undetected |
◎ |
78-93-3 |
Methyl ethyl ketone (MEK) |
CH₃COC₂H₅ |
8 hours undetected |
◎ |
79-20-9 |
Methyl acetate |
CH₃COOCH₃ |
8 hours undetected |
◎ |
67-66-3 |
Chloroform |
CHCl₃ |
8 hours undetected |
◎ |
60-29-7 |
Ethyl ether |
C₂H₅OC₂H₅ |
8 hours undetected |
◎ |
78-83-1 |
Isobutyl alcohol |
(CH₃)₂CHCH₂OH |
8 hours undetected |
◎ |
Estimated : ◎ There is almost no problem even if Used Available Yes
* ASTM (American Society for Testing and materials American Society for Testing and Materials )
※ mark JIS T8116 defined standard test solution
( Our research )
Breakthrough time measurement test(Fluorine-containing rubber)
CAS NO. |
Solvent name |
Chemical formula |
*ASTM breakthrough time |
Indication |
67-64-1 |
※ acetone |
CH₃COCH₃ |
8 hours undetected |
◎ |
27522 |
※ acetonitrile |
CH₃CN |
8 hours undetected |
◎ |
141-78-6 |
※ Ethyl acetate |
CH₃COOC₂H₅ |
8 hours undetected |
◎ |
109-89-7 |
※ diethylamine |
(C₂H₅)₂NH |
8 hours undetected |
◎ |
27639 |
※ dichloromethane |
CH₂Cl₂ |
8 hours undetected |
◎ |
25174 |
※ dimethylformamide (DMF) |
(CH₃)₂NCHO |
8 hours undetected |
◎ |
127-18-4 |
※ tetrachlorethylene |
CCl₂₌CCl₂ |
8 hours undetected |
◎ |
109-99-9 |
※ tetrahydrofuran (THF) |
C₄H₈O |
8 hours undetected |
◎ |
108-88-3 |
※ toluene |
C₆H₅CH₃ |
8 hours undetected |
◎ |
98-95-3 |
※ nitrobenzene |
C₆H₅NO₂ |
8 hours undetected |
◎ |
75-15-0 |
※ carbon disulfide |
CS₂ |
8 hours undetected |
◎ |
110-54-3 |
※ n- hexane |
CH₃(CH₂)₄CH₃ |
8 hours undetected |
◎ |
67-56-1 |
※ methanol |
CH₃OH |
315 minutes |
○ |
7664-93-9 |
※ 93.1% sulfuric acid solution |
H₂SO₄ |
8 hours undetected |
◎ |
1310-73-2 |
※ aqueous solution of sodium hydroxide 50% |
NaOH |
8 hours undetected |
◎ |
872-50-4 |
N- methylpyrrolidone |
C₅H₉NO |
8 hours undetected |
◎ |
512-56-1 |
Trimethyl phosphate |
(CH₃O)₃PO |
8 hours undetected |
◎ |
67-63-0 |
Isopropyl alcohol (IPA) |
CH₃CH(OH)CH₃ |
8 hours undetected |
◎ |
95-47-6 |
0- xylene |
C₆H₄(CH₃)₂ |
8 hours undetected |
◎ |
78-93-3 |
Methyl ethyl ketone (MEK) |
CH₃COC₂H₅ |
8 hours undetected |
◎ |
79-20-9 |
Methyl acetate |
CH₃COOCH₃ |
8 hours undetected |
◎ |
67-66-3 |
Chloroform |
CHCl₃ |
8 hours undetected |
◎ |
60-29-7 |
Ethyl ether |
C₂H₅OC₂H₅ |
8 hours undetected |
◎ |
78-83-1 |
Isobutyl alcohol |
(CH₃)₂CHCH₂OH |
8 hours undetected |
◎ |
Estimation: ◎ Available 〇 Available for short-term work to prevent scattering ✕ Unusable for single use
“Sulfuric acid 96% solution” “Sodium hydroxide aqueous solution 30%”
Test request destination: Chemicals Evaluation and Research Institute
Others examined by our company
* ASTM (American Society for Testing and Materials American Materials Testing Association)
※ mark indicates the standard test solution specified in JIS T 8116